991 resultados para Patient Comfort Rounds


Relevância:

100.00% 100.00%

Publicador:

Resumo:

Hourly rounding in the acute hospital setting has been proposed as an intervention to increase patient satisfaction and safety, and improve the nursing practice environment, but the innovation has not been adequately tested. A quasiexperimental pretest post-test non-randomized parallel group trial design was used to test the effect of hourly patient comfort rounds on patient satisfaction and nursing perceptions of the practice environment, and to evaluate research processes and instruments for a proposed larger study. A Patient Satisfaction Survey instrument was developed and used in conjunction with the Practice Environment Scale of the Nursing Work Index. Results on patient satisfaction showed no significant changes. Significant changes were found for three of the five practice environment subscales. Consistent with the aim of a pilot study, this research has provided important information related to design, instruments and process that will inform a larger sufficiently powered study.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Objective: To measure the prevalence of assessment and management practices for analgesia, sedation and delirium in patients in Australian and New Zealand intensive care units.
Materials and Methods: We developed survey items from a modified Delphi panel and included them in a binational, point prevalence study. We used a standard case report form to capture retrospective patient data on management of analgesia, sedation and delirium at the end of a 4-hour period on the study day. Other data were collected during independent assessment of patient status and medication requirements.
Results: Data were collected on 569 patients in 41 ICUs. Pain assessment was documented in the 4 hours before study observation in 46% of patients. Of 319 assessable patients, 16% had moderate pain and 6% had severe pain. Routine sedation assessment using a scale was recorded in 63% of intubated and ventilated patients. When assessed, 38% were alert and calm, or drowsy and rousable, 22% were lightly to moderately sedated, 31% were deeply sedated (66% of these had a documented indication), and 9% were agitated or restless. Sedatives were titrated to a target level in 42% of patients. Routine assessment of delirium occurred in 3%, and at study assessment 9% had delirium. Wrist or arm restraints were used for 7% of patients.
Conclusions: Only two-thirds of sedated patients had their sedation levels formally assessed, half had pain assessed and very few had formal assessment of delirium. Our description of current practices, and other observational data, may help in planning further research in this area.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

90.00% 90.00%

Publicador:

Resumo:

Aim: To describe the positioning of patients managed in an intensive care unit (ICU); assess how frequently these patients were repositioned; and determine if any specific factors influenced how, why or when patients were repositioned in the ICU. Background: Alterations in body position of ICU patients are important for patient comfort and are believed to prevent and/or treat pressure ulcers, improve respiratory function and combat the adverse effects of immobility. There is a paucity of research on the positioning of critically ill patients in Saudi Arabian ICUs. Design and Methods: A prospective observational study was undertaken. Participant demographic data were collected as were clinical factors (i.e. ventilation status, primary diagnosis, co-morbidities and Ramsay sedation score) and organizational factors (i.e. time of day, type of mattress or beds used, nurse/patient ratio and the patient's position). Clinical and some organization data were recorded over a continuous 48 hour period. Result: Twenty-eight participants were recruited to the study. No participant was managed in either a flat or prone position. Obese participants were most likely to be managed in a supine position. The mean time between turns was two hours. There was no significant association between the mean time between turns and the recorded variables related to patients' demographic and organizational considerations. Conclusion: Results indicate that patient positioning in the ICU was a direct result of unit policy - it appeared that patients were not repositioned based upon evaluation of their clinical condition but rather according to a two-hour ICU timetable

Relevância:

90.00% 90.00%

Publicador:

Resumo:

Review question/objective The review objective is to synthesise the best available evidence on experiences and perceptions of family members of intensive care unit patients on the adequacy of end-of-life care, where life-support modalities have been withheld or withdrawn. Inclusion criteria Types of participants This review will consider studies that report on the experiences and perceptions of patients’ families on EOLC in the ICU, where life-support modalities have been withheld or withdrawn. The family is defined as “those who are closest to the patient... the family may include the biological family, family by acquisition, and the family of choice and friends”. Phenomena of interest The phenomena of interest for this review are the patients’ families experiences, perceptions or views on the adequacy of EOLC delivered in the ICU, where life-support modalities were withheld or withdrawn. These experiences may refer to the following views on domains of care considered important at the end-of-life in the ICU, which have been described already in the existing literature: timely, consistent, and compassionate communication, clinician availability, clinical decision making based on patients’ preferences, goals and values, physical care implemented to maintain patient comfort, holistic interdisciplinary care and bereavement care for families of patients who died.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

L'entraînement par intervalles à haute intensité est plus efficace que l'entraînement continu d’intensité modérée pour améliorer la consommation maximale d’oxygène (VO2max) et le profil métabolique des patients coronariens. Cependant, il n’y a pas de publications pour appuyer la prescription d’un type d’exercice intermittent (HIIE) spécifique dans cette population. Nous avons donc comparé les réponses aiguës cardio-pulmonaires de quatre sessions différentes d’exercice intermittent dans le but d’identifier l’exercice optimal chez les patients coronariens. De manière randomisée, les sujets participaient aux sessions d’HIIE, toutes avec des phases d’exercice à 100% de la puissance maximale aérobie (PMA), mais qui variaient selon la durée des phases d’exercice et de récupération (15s ou 1 min) et la nature de la récupération (0% de la PMA ou 50% de la PMA). Chaque session était réalisée sous forme de temps limite et l’exercice était interrompu après 35 minutes. En considérant l’effort perçu, le confort du patient et le temps passé au-dessus de 80% de VO2max, nous avons trouvé que l’exercice optimal consistait à alterner des courtes phases d’exercice de 15s à 100% de la PMA avec des phases de 15s de récupération passive. Ensuite, nous avons comparé les réponses physiologiques de l’HIIE optimisé avec un exercice continu d’intensité modérée (MICE) iso-calorique chez des patients coronariens. En considérant les réponses physiologiques, l’aspect sécuritaire (aucune élévation de Troponin T) et l’effort perçu, le protocole HIIE est apparu mieux toléré et plus efficace chez ces coronariens. Finalement, une simple session d’HIIE n’induit pas d’effets délétères sur la paroi vasculaire, comme démontré avec l’analyse des microparticules endothéliales. En conclusion, l’exercice intermittent à haute intensité est un mode d'entraînement prometteur pour les patients coronariens stables qui devrait faire l’objet d’autres études expérimentales en particulier pour les patients coronariens ischémiques.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

Study objective: To compare three dressing types in terms of their ability to protect against infection and promote healing, patient comfort, and cost-effectiveness.

Design: Prospective, randomized controlled trial.

Setting: Major metropolitan, academically affiliated, tertiary referral center.

Patients: Seven hundred thirty-seven patients were randomized to receive a dry absorbent dressing (n = 243) [Primapore; Smith & Nephew; Sydney, NSW, Australia], a hydrocolloid dressing (n = 267) [Duoderm Thin ConvaTec; Mulgrave, VIC, Australia], or a hydroactive dressing (n = 227) [Opsite; Smith & Nephew] in the operating theater on skin closure.

Results: There was no difference in the rate of wound infection or wound healing between treatment groups. The Primapore dressing was the most comfortable and cost-effective dressing option for the sternotomy wound. Duoderm Thin dressings were associated with increased wound exudate (p < 0.001), poor dressing integrity (p < 0.001), more frequent dressing changes (p < 0.001), more discomfort with removal (p < 0.05), and increased cost (p < 0.001).

Conclusions: In the context of no additional benefit for the prevention of wound infection or the rate of wound healing for any of the three dressing products examined, dry absorbent dressings are the most comfortable and cost-effective products for sternotomy wounds following cardiac surgery.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

BACKGROUND: An age-controlled comparison concerning patient satisfaction and electrical performance of microfibres (DTL) and rigid contact lens (Henkes) corneal ERG electrodes was carried out. METHODS: 36 test persons underwent complete ophthalmological examination and were equally distributed into 3 age groups. Electroretinograms were recorded according to ISCEV standards. Randomly, in one eye a Henkes electrode was used and in the other eye a DTL electrode. Amplitudes of a- and b-waves and implicit times were measured and compared for the two electrode types. RESULTS: 34 of 36 test persons preferred DTL electrodes. Electrical performance concerning b-wave amplitudes was comparable. Statistically significant differences were detected only for scotopic combined cone-rod stimulation in the age groups 20 - 40 and 41 - 60 years between the different electrodes. Other recordings did not show differences. A statistically significant reduction of signal amplitudes with age was detected for scotopic isolated rod signals and combined cone-rod signals. Significance level was p < 0.05. No conjunctival or corneal erosions were found after ERG recordings for either electrode. CONCLUSIONS: Electrical performance is comparable between electrodes. For scotopic stimulations age was a significant influencing factor for signal amplitude and should be respected for normative values. DTL electrodes were preferred by the vast majority of patients. No adverse clinical effects were observed for either electrode. DTL electrodes should be preferred due to hygienic reasons (single use) and patient comfort.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

Background: Patient discomfort is one reason for poor compliance with supportive periodontal therapy (SPT). The aim of this study was to compare the levels of discomfort during SPT, using the Vector (TM) system and treatment with a conventional ultrasonic scaler. Methods: Forty-six patients with an SPT programme were debrided using both the Vector (TM) system and a conventional piezo-electric scaler (Sirona (TM)) in a split mouth design. A visual analogue scale was used to evaluate of pain scores upon completion of treatment. A verbal response scale(VRS) was used to assess discomfort, vibration and noise associated with the scaling system, as well as the volume and taste of the coolant used by these systems. Results: Patients instrumented with the Vector (TM) system experienced approximately half the amount of pain compared with the conventional ultrasonic scaling system. The VRS showed that the Vector (TM) system caused less discomfort than the conventional ultrasonic scaling system when assessed for pain, vibration, noise and volume of coolant. These findings were all statistically significant. There was, however, no statistically significant difference between the two systems when assessed for taste. Conclusion: During SPT the Vector (TM) system caused reduced discomforting sensations compared with conventional methods and may be useful in improving compliance with SPT programmes.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Contact lenses are a common method for the correction of refractive errors of the eye. While there have been significant advancements in contact lens designs and materials over the past few decades, the lenses still represent a foreign object in the ocular environment and may lead to physiological as well as mechanical effects on the eye. When contact lenses are placed in the eye, the ocular anatomical structures behind and in front of the lenses are directly affected. This thesis presents a series of experiments that investigate the mechanical and physiological effects of the short-term use of contact lenses on anterior and posterior corneal topography, corneal thickness, the eyelids, tarsal conjunctiva and tear film surface quality. The experimental paradigm used in these studies was a repeated measures, cross-over study design where subjects wore various types of contact lenses on different days and the lenses were varied in one or more key parameters (e.g. material or design). Both, old and newer lens materials were investigated, soft and rigid lenses were used, high and low oxygen permeability materials were tested, toric and spherical lens designs were examined, high and low powers and small and large diameter lenses were used in the studies. To establish the natural variability in the ocular measurements used in the studies, each experiment also contained at least one “baseline” day where an identical measurement protocol was followed, with no contact lenses worn. In this way, changes associated with contact lens wear were considered in relation to those changes that occurred naturally during the 8 hour period of the experiment. In the first study, the regional distribution and magnitude of change in corneal thickness and topography was investigated in the anterior and posterior cornea after short-term use of soft contact lenses in 12 young adults using the Pentacam. Four different types of contact lenses (Silicone hydrogel/ Spherical/–3D, Silicone Hydrogel/Spherical/–7D, Silicone Hydrogel/Toric/–3D and HEMA/Toric/–3D) of different materials, designs and powers were worn for 8 hours each, on 4 different days. The natural diurnal changes in corneal thickness and curvature were measured on two separate days before any contact lens wear. Significant diurnal changes in corneal thickness and curvature within the duration of the study were observed and these were taken into consideration for calculating the contact lens induced corneal changes. Corneal thickness changed significantly with lens wear and the greatest corneal swelling was seen with the hydrogel (HEMA) toric lens with a noticeable regional swelling of the cornea beneath the stabilization zones, the thickest regions of the lenses. The anterior corneal surface generally showed a slight flattening with lens wear. All contact lenses resulted in central posterior corneal steepening, which correlated with the relative degree of corneal swelling. The corneal swelling induced by the silicone hydrogel contact lenses was typically less than the natural diurnal thinning of the cornea over this same period (i.e. net thinning). This highlights why it is important to consider the natural diurnal variations in corneal thickness observed from morning to afternoon to accurately interpret contact lens induced corneal swelling. In the second experiment, the relative influence of lenses of different rigidity (polymethyl methacrylate – PMMA, rigid gas permeable – RGP and silicone hydrogel – SiHy) and diameters (9.5, 10.5 and 14.0) on corneal thickness, topography, refractive power and wavefront error were investigated. Four different types of contact lenses (PMMA/9.5, RGP/9.5, RGP/10.5, SiHy/14.0), were worn by 14 young healthy adults for a period of 8 hours on 4 different days. There was a clear association between fluorescein fitting pattern characteristics (i.e. regions of minimum clearance in the fluorescein pattern) and the resulting corneal shape changes. PMMA lenses resulted in significant corneal swelling (more in the centre than periphery) along with anterior corneal steepening and posterior flattening. RGP lenses, on the other hand, caused less corneal swelling (more in the periphery than centre) along with opposite effects on corneal curvature, anterior corneal flattening and posterior steepening. RGP lenses also resulted in a clinically and statistically significant decrease in corneal refractive power (ranging from 0.99 to 0.01 D), large enough to affect vision and require adjustment in the lens power. Wavefront analysis also showed a significant increase in higher order aberrations after PMMA lens wear, which may partly explain previous reports of "spectacle blur" following PMMA lens wear. We further explored corneal curvature, thickness and refractive changes with back surface toric and spherical RGP lenses in a group of 6 subjects with toric corneas. The lenses were worn for 8 hours and measurements were taken before and after lens wear, as in previous experiments. Both lens types caused anterior corneal flattening and a decrease in corneal refractive power but the changes were greater with the spherical lens. The spherical lens also caused a significant decrease in WTR astigmatism (WRT astigmatism defined as major axis within 30 degrees of horizontal). Both the lenses caused slight posterior corneal steepening and corneal swelling, with a greater effect in the periphery compared to the central cornea. Eyelid position, lid-wiper and tarsal conjunctival staining were also measured in Experiment 2 after short-term use of the rigid and SiHy contact lenses. Digital photos of the external eyes were captured for lid position analysis. The lid-wiper region of the marginal conjunctiva was stained using fluorescein and lissamine green dyes and digital photos were graded by an independent masked observer. A grading scale was developed in order to describe the tarsal conjunctival staining. A significant decrease in the palpebral aperture height (blepharoptosis) was found after wearing of PMMA/9.5 and RGP/10.5 lenses. All three rigid contact lenses caused a significant increase in lid-wiper and tarsal staining after 8 hours of lens wear. There was also a significant diurnal increase in tarsal staining, even without contact lens wear. These findings highlight the need for better contact lens edge design to minimise the interactions between the lid and contact lens edge during blinking and more lubricious contact lens surfaces to reduce ocular surface micro-trauma due to friction and for. Tear film surface quality (TFSQ) was measured using a high-speed videokeratoscopy technique in Experiment 2. TFSQ was worse with all the lenses compared to baseline (PMMA/9.5, RGP/9.5, RGP/10.5, and SiHy/14) in the afternoon (after 8 hours) during normal and suppressed blinking conditions. The reduction in TFSQ was similar with all the contact lenses used, irrespective of their material and diameter. An unusual pattern of change in TFSQ in suppressed blinking conditions was also found. The TFSQ with contact lens was found to decrease until a certain time after which it improved to a value even better than the bare eye. This is likely to be due to the tear film drying completely over the surface of the contact lenses. The findings of this study also show that there is still a scope for improvement in contact lens materials in terms of better wettability and hydrophilicity in order to improve TFSQ and patient comfort. These experiments showed that a variety of changes can occur in the anterior eye as a result of the short-term use of a range of commonly used contact lens types. The greatest corneal changes occurred with lenses manufactured from older HEMA and PMMA lens materials, whereas modern SiHy and rigid gas permeable materials caused more subtle changes in corneal shape and thickness. All lenses caused signs of micro-trauma to the eyelid wiper and palpebral conjunctiva, although rigid lenses appeared to cause more significant changes. Tear film surface quality was also significantly reduced with all types of contact lenses. These short-term changes in the anterior eye are potential markers for further long term changes and the relative differences between lens types that we have identified provide an indication of areas of contact lens design and manufacture that warrant further development.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Aim To develop clinical practice guidelines for nurse-administered procedural sedation and analgesia in the cardiac catheterisation laboratory. Background Numerous studies have reported that nurse-administered procedural sedation and analgesia is safe. However, the broad scope of existing guidelines for the administration and monitoring of patients who receive sedation during medical procedures without an anaesthetist presents means there is a lack of specific guidance regarding optimal nursing practices for the unique circumstances in which nurse-administered procedural sedation and analgesia is used in the cardiac catheterisation laboratory. Methods A sequential mixed methods design was utilised. Initial recommendations were produced from three studies conducted by the authors: an integrative review; a qualitative study; and a cross-sectional survey. The recommendations were revised in accordance with responses from a modified Delphi study. The first Delphi round was completed by nine senior cardiac catheterisation laboratory nurses. All but one of the draft recommendations met the pre-determined cut-off point for inclusion. There were a total of 59 responses to the second round. Consensus was reached on all recommendations. Implications for nursing The guidelines that were derived from the Delphi study offer twenty four recommendations within six domains of nursing practice: Pre-procedural assessment; Pre-procedural patient and family education; Pre-procedural patient comfort; Intra-procedural patient comfort; Intra-procedural patient assessment and monitoring; and Post-procedural patient assessment and monitoring. Conclusion These guidelines provide an important foundation towards the delivery of safe, consistent and evidence-based nursing care for the many patients who receive sedation in the cardiac catheterisation laboratory setting.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Oral endotracheal tubes (ETTs) and nasogastric tubes (NGT) are common devices used in adult intensive care and numerous options exist for safe and comfortable securement of these devices. The aim of this project was to identify the available range of ETT and NGT securement devices in Australia as a resource for clinicians seeking to explore options for tube stabilisation. This article reports part A of this project: ETT securement options. Part B will report NGT device fixation options. Securing ETTs to ensure a patent airway with minimal ETT movement, promotion of patient comfort and absence of adverse events such as ETT dislodgement, unplanned extubation and device-related injury1, are essential critical care nursing actions. The ETT requires a fixation method that is robust yet does not traumatise or injure the mucosal tissues of the mouth and soft tissue of the lips.2,3 Choice of a securement apparatus is often determined by product availability in our units or hospitals but is also driven by evidence-based practice and clinician preference. Trying to put this information together can be difficult and time-consuming for the bedside clinician...

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Purpose To establish whether the use of a passive or active technique of planning target volume (PTV) definition and treatment methods for non-small cell lung cancer (NSCLC) deliver the most effective results. This literature review assesses the advantages and disadvantages in recent studies of each, while assessing the validity of the two approaches for planning and treatment. Methods A systematic review of literature focusing on the planning and treatment of radiation therapy to NSCLC tumours. Different approaches which have been published in recent articles are subjected to critical appraisal in order to determine their relative efficacy. Results Free-breathing (FB) is the optimal method to perform planning scans for patients and departments, as it involves no significant increase in cost, workload or education. Maximum intensity projection (MIP) is the fastest form of delineation, however it is noted to be less accurate than the ten-phase overlap approach for computed tomography (CT). Although gating has proven to reduce margins and facilitate sparing of organs at risk, treatment times can be longer and planning time can be as much as 15 times higher for intensity modulated radiation therapy (IMRT). This raises issues with patient comfort and stabilisation, impacting on the chance of geometric miss. Stereotactic treatments can take up to 3 hours to treat, along with increases in planning and treatment, as well as the additional hardware, software and training required. Conclusion Four-dimensional computed tomography (4DCT) is superior to 3DCT, with the passive FB approach for PTV delineation and treatment optimal. Departments should use a combination of MIP with visual confirmation ensuring coverage for stage 1 disease. Stages 2-3 should be delineated using ten-phases overlaid. Stereotactic and gated treatments for early stage disease should be used accordingly; FB-IMRT is optimal for latter stage disease.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

O objetivo geral deste estudo foi: Verificar se a introdução dos princípios da teoria do conforto de Katherine Kolcaba na consulta de enfermagem para pacientes com IC sob cuidados paliativos a partir da sistematização da assistência utilizando as taxonominas NANDA-NOC-NIC promove maior conforto. Trata-se de um ensaio clínico aberto, tipo antes e depois, realizado em hospital federal localizado no Rio de Janeiro com amostra de 20 pacientes. Para avaliação do conforto, utilizou-se o questionário End of life comfort questionnaire patient e o resultado de enfermagem (NOC - Estado de Conforto). As avaliações do questionário ocorreram nas primeira, terceira e sexta consultas de enfermagem e o NOC em todas as consultas. A coleta de dados foi realizada entre os meses de novembro de 2012 e maio de 2013. Utilizou-se o programa SPSS 19.0 para análise dos dados. Foram utilizados os Testes Qui-Quadrado, Exato de Fisher e Mann-Whitney para verificar a associação dos diagnósticos e intervenções de enfermagem com o conforto aferido pelo questionário nos três tempos aplicados. Foi utilizado o Teste ANOVA (análise de variância) para avaliar a melhora na condição de conforto dos sujeitos através do questionário já descrito e também pela NOC Estado de Conforto verificada nas seis consultas. Como resultado encontrou-se três diagnósticos de enfermagem e duas intervenções de enfermagem relacionadas à maior conforto dos pacientes (p <0,05). Já associados ao menor conforto foram encontrados 08 diagnósticos e 12 intervenções. O conforto verificado pelo questionário e o resultado de enfermagem aumentaram significativamente (p <0,001) durante os 06 meses de acompanhamento. A aceitação da hipótese alternativa (a introdução dos princípios da teoria de Katherine Kolcaba na consulta de enfermagem está associada ao maior conforto dos pacientes com insuficiência cardíaca sob cuidados paliativos), se confirmou. O estudo contribuiu para reafirmar que quando se utiliza uma teoria de enfermagem para sustentar a prática/pesquisa da profissão, o desenvolvimento da sistematização da assistência se torna mais claro. A implementação da teoria faz com que o desfecho do cuidar em enfermagem se torne visível a outras profissões e à sociedade em geral.